Southern Alberta Type 1-S Manholes


  Description For Pipe
Sizes
up to
Approx. Weight
(kg) each piece/
each half
Dimension
A B&C D E F G
1.2 1S Top & Bottom Half 2020 High 900 2650 175 1010 200 150 1200 1500
1000 High Intermediate - 2040 - 1000 - 150 1200 1500
Top Half 1010 High 675 2650 175 1010 200 150 1200 1500
Flat Base Slab - 1620 - - 250 - - 1500
1.5 1S Top & Bottom Half 2020 High 1050 3550 175 1010 200 150 1500 1800
1000 High Intermediate - 2400 - 1000 - 150 1500 1800
Top Half 1010 High 675 2650 175 1010 200 150 1500 1800
Flat Base Slab - 2330 - - 250 - - 1800
1.9 1S Top & Bottom Half 2000 High 1500 5650 200 1000 200 150 1930 2230
1000 High Intermediate - 3100 - 1000 - 150 1930 2230
Top Half 1000 High 675 5650 200 1010 200 150 1930 2230
Flat Base Slab - 3580 - - 250 - - 2230
2.4 1S Top & Bottom Half 2400 High 1800 11680 250 1200 250 230 2400 2860
1000 High Intermediate - 5700 - 1000 - 230 2400 2860
1750 High Intermediate   10000 - 1750 - 230 2400 2860
Top Half 1200 High 900 11680 250 1200 250 230 2400 2860
Flat Base Slab - 5890 - - 250 - - 2860
1.9 1S Top & Bottom Half 2800 High 2100 18140 250 1400 250 230 2800 3260
1750 High Intermediate - 11500 - 1400 - 230 2800 3260
Top Half 1400 High 1050 18140 250 1400 250 230 2800 3260
Flat Base Slab - 7650 - - 250 - - 3260

Notes:

  1. 1-S Manholes are NOT prebenched.
  2. Non-standard hole sizes and angle entry holes available.
  3. Standard depth of cover is 5m.
  4. Use intermediate sections between top and bottom sections of 1-S manhole to meet drop manhole invert requirements.
  5. Where design invert rim to invert is less than the minimum shown, the City of Calgary requires a complete top and bottom be used, in which case it must be lowered and field benched to invert. Elsewhere, a top half 1-S plus a base slab may be used, subject to approval by project engineer.
  6. Type 1-S skimming manholes with formed channels available in all sizes.
  7. Kent Seal gasket is available for Type 1S manhole joints but is very dependent on field installation. Additional measures by contractor may be needed if a watertight joint is required.
  8. Top and bottom half walls taper from the thickest point at the top/base slab to the centre (dimension 'E'). This may affect mounting of equipment, gates, etc.

Plan

Section


 
Plan Size
(mm)
Maximum Angle off of Face for Type 1S Manhole Size:
1200mm 1500mm 1930mm 2400mm 2800mm
300 45 45 45 45 45
375 45 45 45 45 45
450 45 45 45 45 45
525 40 45 45 45 45
600 35 45 45 45 45
675 30 45 45 45 45
750 25 40 45 45 45
900 0 30 45 45 45
1050 - 15 40 45 45
1200 - - 30 45 45
1350 - - 20 40 45
1500 - - 10 30 40
1650 - - - 25 35
1800 - - - 10 30
1950 - - - - 20
2100 - - - - 15

Notes:

  1. If pipe angle is greater than shown, use larger manhole.


Plan View