Non-standard hole sizes and angle entry holes available.
Standard depth of cover is 5m.
Use intermediate sections between top and bottom sections of 1-S manhole to meet drop manhole invert requirements.
Where design invert rim to invert is less than the minimum shown, the City of Calgary requires a complete top and bottom be used,
in which case it must be lowered and field benched to invert. Elsewhere, a top half 1-S plus a base slab may
be used, subject to approval by project engineer.
Type 1-S skimming manholes with formed channels available in all sizes.
Kent Seal gasket is available for Type 1S
manhole joints but is very dependent on field installation.
Additional measures by contractor may be needed if a
watertight joint is required.
Top and bottom half walls taper from the thickest point at
the top/base slab to the centre (dimension 'E'). This may
affect mounting of equipment, gates, etc.
Plan
Section
Plan Size (mm)
Maximum Angle off of Face for Type 1S Manhole Size:
1200mm
1500mm
1930mm
2400mm
2800mm
300
45
45
45
45
45
375
45
45
45
45
45
450
45
45
45
45
45
525
40
45
45
45
45
600
35
45
45
45
45
675
30
45
45
45
45
750
25
40
45
45
45
900
0
30
45
45
45
1050
-
15
40
45
45
1200
-
-
30
45
45
1350
-
-
20
40
45
1500
-
-
10
30
40
1650
-
-
-
25
35
1800
-
-
-
10
30
1950
-
-
-
-
20
2100
-
-
-
-
15
Notes:
If pipe angle is greater than shown, use larger manhole.